Autodesk Navisworks object enablers
I have had several calls about Autodesk
Navisworks not recognizing certain objects when
you open a DWG file that was created in AutoCAD Building
Systems 2007, AutoCAD MEP 2008, or AutoCAD MEP 2009. Objects
are most often displayed as proxy graphics. Sometimes a
message is shown stating that the object enabler is missing.
In order to convert the objects, Autodesk Navisworks needs
to have the correct object enablers loaded. This is not a
new concept for Autodesk products and has been the case
since the first vertical product was developed. You need to
install the corresponding object enabler, regardless of
whether the AutoCAD application is installed or not. This
applies to all AutoCAD-based products released in 2007, 2008
and 2009.
The delicate part of this process is knowing which ones need
to be installed. If you are running Autocad MEP then you
need to load the MEP object enablers, right? Sort of. The
MEP object enablers build on the Architecture Object
enablers, so you have to have the Architecture object
enablers installed first. The AutoCAD
Architectural Desktop or AutoCAD Architecture
object enablers must be configured with Navisworks first in
order for the AutoCAD ABS and AutoCAD MEP object enabler
installers to recognize that Navisworks is installed on the
computer.
Now that you have the order correct, make sure you have the
correct version. If you want to see ABS 2007 objects then
you need to install the Architectural Desktop 2007 object
enablers and then the ABS 2007 object enablers.
Again, it doesnt matter if the software is already
installed on the machine. You will still need to install the
object enablers for Navisworks.
If you have already tried some of these and are not getting
the desired results, follow the steps below. Again, make
sure you are using the correct version of the object
enablers.
-
Uninstall the MEP object enablers and the Architecture
object enablers if they are already installed.
-
Download and install the object enablers in the
following order:
-
AutoCAD Architecture/Architectural Desktop object
enabler:
See list below
-
AutoCAD MEP/Building Systems object enabler:
See list below
-
Any other 3rd party object enablers for Autodesk
products
-
Open Navisworks.
-
Click Tools menu > Global Options > File Readers > DWG/DXF/SAT.
-
Set the DWG Loader version to the version of the
software you are loading.
-
Exit Navisworks.
-
Delete any NWC cache files associated with your model.
-
Start Navisworks.
-
Open your model.
For 2007
files
Architectural Desktop Object Enabler 2007
Autodesk Building Systems 2007 Object Enabler
For 2008
files
AutoCAD Architecture 2008 Object Enabler
AutoCAD MEP 2008 Object Enabler
For 2009
files
AutoCAD Architecture 2009 Object Enabler
AutoCAD MEP 2009 Object Enabler